 | Host: Wabash National – Mike Holle |
 | Speaker: Paul Lorkowski – Capital Safety |
 | Topic: Proposed changes to ANSI Z359.1 standard |
 | Main change: gate strength from 220# to 3600#. |
 | Gate face: 220# to 3600#. |
 | Side of gate: 350# to 3600#. |
 | Passed “old” & “new” gates around room for review. |
 | New ratings will be stamped on gate. |
 | Front “D” on harness can now be used for fall
arrest. |
 | Twin leg lanyards…minimum of 5,000# break
strength. Connect only center snap hook to fall arrest attachment. |
 | The term “user” has been clarified by “competent”,
“qualified”, and “authorized” persons. |
 | If one or more persons are routinely exposed to
fall hazards, a comprehensive managed fall protection program is
required. |
 | Introduced new “tie back” lanyard. |
 | Duties and responsibilities were discussed for
each person associated with comprehensive fall protection program. |
 | Anchorage system: Minimum 5,000#.
 | Rule of thumb – anchor point must be able to
support weight of pick up truck. |
|
 | Addressed rescue procedures when needed and what
is required. |
 | Systems, sub-systems, and components required for
rescue. |
 | Discussed increased awareness in the values of
expanded fall protection standard. |