 | Denny introduced Brian Sebastian with MSA and
presented him with a gift certificate to Advantage Embroidery. |
 | Bump testing is a performed test of a known gas
over sensors to assure accurate performance. |
 | If a bump test fails, adjustments must be made to
bring instrument into proper working order. |
 | Verify calibration gas has not expired. |
 | Verify that the correct gas is being used. |
 | Allow sensors to stabilize (45 second minimum). |
 | If sensor(s) fail, calibrate. |
 | When should you calibrate?
 | When bump test fails. |
 | If unit has recently been serviced. |
 | Per companies safety procedure. |
 | When instrument has been dropped. |
 | New sensor has been placed into unit. |
 | When calibration drift is occurring. |
|
 | Performing a calibration.
 | Verify you are using right cal gas. |
 | Verify the bottle hasn’t expired. |
 | Attach gas using proper cal cap attachment. |
 | Follow manufacturer’s steps to accessing auto
calibration feature. |
 | Record calibration values AF/AL #. (AF =
Actual Found) (AL = Actual Left) |
 | Or use test station. |
|
 | New PremAire Cadet Escape.
 | 3 size cylinders. |
 | New 1 piece cylinder valve/first stage
regulator. |
 | Waist belt reinforced. |
 | Left or right hip. |
 | Strain relief. |
 | Ultra Elite/Adv 4000 |
 | PTC/STC |
|
 | Altair.
 | IP67 |
 | Non-direct reading |
 | 24 mos. disposable. |
 | H2S, CO, O2 |
 | Audible, visual, & vibrating alarms. |
 | Maintenance free. |
 | 18 hour alarm time. |
|
 | Altair Pro.
 | IP67 |
 | Direct read. |
 | Replaceable sensor & battery. |
 | CR2 battery. |
 | H2S, CO, O2, S02, HCN, NH3, etc. |
 | Replaceable front display. |
 | 2 year comprehensive warranty. |
 | Adjustable alarm levels. |
|
 | New Altair Four.
 | Detects O2, CO, H2S, combustible gas. |
 | Li-polymer battery. |
 | Visible alarms 360 |
 | Robust/rubberized/impact. |
 | Drop test 10’. |
 | IP67. |
 | Motion Alert. |
 | Instant Alert Standard. |
 | Confidence signal. |
 | Bump check mark (24 hours). |
 | Pump version available. |
 | Datalog standard. |
|
 | Orion.
 | IP54 |
 | Internal pump. |
 | Alkaline/Ni MH battery. |
 | 2 year warranty/lifetime. |
 | LeI/CH4, O2, CO, H2S |
 | 6’ drop test. |
 | Electrical flow pump. |
|
 | Sirius.
 | IP54. |
 | Alkaline/Li-Ion. |
 | 2 year warranty. |
 | 9.8/10.6 amp |
 | 100 Preprogrammed chemicals. |
 | Five (5) favorites. |
 | Internal pump. |
|
 | Quick Check.
 | Compatible with all Altair/Altair Pro. |
 | Maintenance free. |
 | Provides quick bump test checking. |
 | Check marks unit for 24 hours. |
 | Test time less than 30 seconds. |
|
 | Galaxy.
 | On demand. |
 | Battery/120V |
 | Up to 10 units. |
 | Internet capable. |
 | Bump/cal/bump fail cal. |
 | Data download card. |
 | Calibrates all together. |
 | Printer optional. |
|